Front RangePlant FinderDesign my yard

Defensible space: the three zones around your house

Written by · Reviewed against CSU Extension & Plant Select® · Updated 2026-10-30

Quick answer

Defensible space is the area around a house that has been modified to reduce fire hazards by putting space between fuels. CSU Extension and the Colorado State Forest Service split it into three zones measured from the edge of the house: Zone 1 is 0-5 ft, Zone 2 is 5-30 ft and Zone 3 is 30-100 ft. The closer the zone, the stricter the rules.

None of this needs a bulldozer. Most of it is raking, pruning, mowing and choosing what goes where, done closest to the house first.

Why it works

CSU's Fire-Adapted Landscaping Practices says wildfire behavior comes down largely to two things: fuel continuity, meaning how burnable things sit relative to each other, and fuel loading, meaning how much burnable material there is. Defensible space breaks the chain and shrinks the pile.

Embers are the other half. Structures usually catch from firebrands that can travel long distances, which is why the 5 feet against the walls gets the strictest treatment. CSU's order of work: harden the house first (roofing, siding, decks, fences), then Zone 1, then outward. Together the three zones are what CSU calls the home ignition zone, the area within 100 feet of a structure.

Defensible space zones around a houseA house seen from above with three rings around it: Zone 1, 0-5 ft, gravel and no plants that burn easily; Zone 2, 5-30 ft, small islands of low plants; Zone 3, 30-100 ft, widely spaced trees. Not to scale.HouseZone 330-100 ftZone 25-30 ftZone 10-5 ft
Zones are measured from the edge of the house, eaves, decks and stairs included. Not to scale.

Zone 1: 0-5 ft

The goal, in CSU's words: keep fire or firebrands from igniting materials that can spread fire directly to the house.

California numbers its zones from 0: its Zone 0 is the same first 5 feet, called the ember-resistant zone, with its own state rule set, so California readers should follow CAL FIRE's defensible space page instead of this page.

Zone 2: 5-30 ft

The goal: lower the fire's intensity as it gets near the house by limiting the fuel it can reach.

Zone 3: 30-100 ft

The goal: cut the amount and connectedness of fuel so a fire stays on the ground.

How much defensible space do I need?

CSU's zones run 100 feet out from the house, so that is the full target, with the effort weighted toward the first 30 feet. Two things change the picture. Slope: CSU says fuel breaks do less on steep ground and evergreens need more room between crowns there. Lot size: on smaller lots the zones overlap the neighbors' yards, Zone 3 especially, which makes it a shared project. In CSU's words, a group of structures is only as protected as its least prepared member.

Slope and local code can change this; ask your fire district or the nearest Colorado State Forest Service field office or county Extension office, which CSU names as the places to get a defensible space plan for a specific property.

Plants for each zone

No plant is fireproof. CSU Extension's Fact Sheet 6.305 says all vegetation, naturally occurring or planted, is potential fuel. A high score means a plant is less ignitable, not that it will not burn.

The full ranked list, with save buttons, is on the Colorado fire-resistant plants page. For mulch choices, spacing and seasonal upkeep, see the fire-resistant landscaping guide.

Frequently asked questions

What is the home ignition zone?
CSU's name for the three defensible space zones together: everything within 100 feet of a structure. Looking after it, along with hardening the house itself, raises the odds a house survives a wildfire.
How far should plants be from my house?
CSU Extension's ideal for the first 5 feet is non-combustible ground. If you do plant there, use plants scoring 8 or higher on CSU's ignitability scale (the same bar CSU sets out to 30 feet), keep the nearest branch at least 5 feet from the house, and keep the area clear of dry leaves and needles.
Can I use mulch near my house?
Not wood. CSU says not to use wood chips, bark, pine needles or shredded rubber within 5 feet of a structure. Out to 30 feet, gravel is the preferred mulch, and landscape fabric should not go under it.
Do I need to cut down my trees?
Usually not all of them. CSU's advice is to thin evergreens to 10 to 15 feet between canopies, remove shrubs beneath trees, limb trees up 6 to 10 feet without taking more than a third of the height, and remove dead or dying trees. New evergreens should not go in zone 2, 5 to 30 feet out.

Sources

Ignitability scores come from CSU Extension Fact Sheet 6.305. Plants that only Plant Select lists carry no score and are shown for the zone 2 area only. Placement and maintenance guidance comes from Fact Sheet 6.303, which rates no plants.